|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LEED for New Construction v2.2 |
|
|
|
|
|
|
|
|
Registered Project Checklist |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Project Name: Riverbend |
|
Project Address: 13112 Telecom Drive, Tampa, FL 33637 |
|
|
|
|
|
|
|
|
|
|
Yes |
? |
No |
|
|
|
|
|
|
9 |
|
5 |
|
Sustainable Sites |
14 Points |
|
|
|
|
|
|
|
|
|
|
Y |
|
|
Prereq 1 |
Construction Activity Pollution Prevention |
Required |
|
|
|
1 |
Credit 1 |
Site Selection |
1 |
|
|
|
1 |
Credit 2 |
Development Density & Community Connectivity |
1 |
|
|
|
1 |
Credit 3 |
Brownfield Redevelopment |
1 |
|
1 |
|
|
Credit 4.1 |
Alternative Transportation, Public Transportation Access |
1 |
|
1 |
|
|
Credit 4.2 |
Alternative Transportation, Bicycle Storage & Changing Rooms |
1 |
|
1 |
|
|
Credit 4.3 |
Alternative Transportation, Low-Emitting & Fuel Efficient Vehicles |
1 |
|
1 |
|
|
Credit 4.4 |
Alternative Transportation, Parking Capacity |
1 |
|
|
|
1 |
Credit 5.1 |
Site Development, Protect and Restore Habitat |
1 |
|
1 |
|
|
Credit 5.2 |
Site Development, Maximize Open Space |
1 |
|
1 |
|
|
Credit 6.1 |
Stormwater Design, Quantity Control |
1 |
|
1 |
|
|
Credit 6.2 |
Stormwater Design, Quality Control |
1 |
|
|
|
1 |
Credit 7.1 |
Heat Island Effect, Non-Roof |
1 |
|
1 |
|
|
Credit 7.2 |
Heat Island Effect, Roof |
1 |
|
1 |
|
|
Credit 8 |
Light Pollution Reduction |
1 |
|
Yes |
? |
No |
|
|
|
|
|
|
3 |
|
2 |
|
Water Efficiency |
5 Points |
|
|
|
|
|
|
|
|
|
|
1 |
|
|
Credit 1.1 |
Water Efficient Landscaping, Reduce by 50% |
1 |
|
|
|
1 |
Credit 1.2 |
Water Efficient Landscaping, No potable Use or No Irrigation |
1 |
|
|
|
1 |
Credit 2 |
Innovative Wastewater Technologies |
1 |
|
1 |
|
|
Credit 3.1 |
Water Use Reduction, 20% Reduction |
1 |
|
1 |
|
|
Credit 3.2 |
Water Use Reduction, 30% Reduction |
1 |
|
|
|
|
|
|
|
|
|
|
5 |
|
5 |
|
Energy & Atmosphere |
17 Points |
|
|
|
|
|
|
|
|
|
|
Y |
|
|
Prereq 1 |
Fundamental Commissioning of the Building Energy Systems |
Required |
|
Y |
|
|
Prereq 2 |
Minimum Energy Performance |
Required |
|
Y |
|
|
Prereq 3 |
Fundamental Refrigerant Management |
Required |
|
3 |
|
|
Credit 1 |
Optimize Energy Performance |
1 to 10 |
|
|
|
|
|
|
|
10.5% New Buildings or 3.5% Existing Building Renovations |
1 |
|
|
|
|
|
|
|
14% New Buildings or 7% Existing Building Renovations |
2 |
|
|
|
|
|
|
3 |
17.5% New Buildings or 10.5% Existing Building Renovations |
3 |
|
|
|
|
|
|
|
21% New Buildings or 14% Existing Building Renovations |
4 |
|
|
|
|
|
|
|
24.5% New Buildings or 17.5% Existing Building Renovations |
5 |
|
|
|
|
|
|
|
28% New Buildings or 21% Existing Building Renovations |
6 |
|
|
|
|
|
|
|
31.5% New Buildings or 24.5% Existing Building Renovations |
7 |
|
|
|
|
|
|
|
35% New Buildings or 28% Existing Building Renovations |
8 |
|
|
|
|
|
|
|
38.5% New Buildings or 31.5% Existing Building Renovations |
9 |
|
|
|
|
|
|
|
42% New Buildings or 35% Existing Building Renovations |
10 |
|
|
|
3 |
Credit 2 |
On-Site Renewable Energy |
1 to 3 |
|
|
|
|
|
|
|
2.5% Renewable Energy |
1 |
|
|
|
|
|
|
|
7.5% Renewable Energy |
2 |
|
|
|
|
|
|
|
12.5% Renewable Energy |
3 |
|
1 |
|
|
Credit 3 |
Enhanced Commissioning |
1 |
|
|
|
1 |
Credit 4 |
Enhanced Refrigerant Management |
1 |
|
|
|
1 |
Credit 5 |
Measurement & Verification |
1 |
|
1 |
|
|
Credit 6 |
Green Power |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
continued… |
|
Yes |
? |
No |
|
|
|
|
|
|
8 |
|
5 |
|
Materials & Resources |
13 Points |
|
|
|
|
|
|
|
|
|
|
Y |
|
|
Prereq 1 |
Storage & Collection of Recyclables |
Required |
|
|
|
1 |
Credit 1.1 |
Building Reuse, Maintain 75% of Existing Walls, Floors & Roof |
1 |
|
|
|
1 |
Credit 1.2 |
Building Reuse, Maintain 100% of Existing Walls, Floors & Roof |
1 |
|
|
|
1 |
Credit 1.3 |
Building Reuse, Maintain 50% of Interior Non-Structural Elements |
1 |
|
1 |
|
|
Credit 2.1 |
Construction Waste Management, Divert 50% from Disposal |
1 |
|
1 |
|
|
Credit 2.2 |
Construction Waste Management, Divert 75% from Disposal |
1 |
|
1 |
|
|
Credit 3.1 |
Materials Reuse, 5% |
1 |
|
1 |
|
|
Credit 3.2 |
Materials Reuse,10% |
1 |
|
1 |
|
|
Credit 4.1 |
Recycled Content, 10% (post-consumer + 1/2 pre-consumer) |
1 |
|
1 |
|
|
Credit 4.2 |
Recycled Content, 10% (post-consumer + 1/2 pre-consumer) |
1 |
|
1 |
|
|
Credit 5.1 |
Regional Materials, 10% Extracted & Manufactured Regionally |
1 |
|
1 |
|
|
Credit 5.2 |
Regional Materials, 20% Extracted & Manufactured Regionally |
1 |
|
|
|
1 |
Credit 6 |
Rapidly Renewable Materials |
1 |
|
|
|
1 |
Credit 7 |
Certified Wood |
1 |
|
Yes |
? |
No |
|
|
|
|
|
|
12 |
|
3 |
|
Indoor Environmental Quality |
15 Points |
|
|
|
|
|
|
|
|
|
|
Y |
|
|
Prereq 1 |
Minimum IAQ Performance |
Required |
|
Y |
|
|
Prereq 2 |
Environmental Tobacco Smoke |
Required |
|
1 |
|
|
Credit 1 |
Outdoor Air Delivery Monitoring |
1 |
|
1 |
|
|
Credit 2 |
Increased Ventilation |
1 |
|
1 |
|
|
Credit 3.1 |
Construction IAQ Management Plan, During Construction |
1 |
|
|
|
1 |
Credit 3.2 |
Construction IAQ Management Plan, Before Occupancy |
1 |
|
|
|
1 |
Credit 4.1 |
Low-Emitting Materials, Adhesives & Sealants |
1 |
|
1 |
|
|
Credit 4.2 |
Low-Emitting Materials, Paints & Coatings |
1 |
|
1 |
|
|
Credit 4.3 |
Low-Emitting Materials, Carpet Systems |
1 |
|
|
|
1 |
Credit 4.4 |
Low-Emitting Materials, Composite Wood & Agrifiber Products |
1 |
|
1 |
|
|
Credit 5 |
Indoor Chemical & Pollutant Source Control |
1 |
|
1 |
|
|
Credit 6.1 |
Controllability of Systems, Lighting |
1 |
|
1 |
|
|
Credit 6.2 |
Controllability of Systems, Thermal Comfort |
1 |
|
1 |
|
|
Credit 7.1 |
Thermal Comfort, Design |
1 |
|
1 |
|
|
Credit 7.2 |
Thermal Comfort, Verification |
1 |
|
1 |
|
|
Credit 8.1 |
Daylight & Views, Daylight 75% of Spaces |
1 |
|
1 |
|
|
Credit 8.2 |
Daylight & Views, Views for 90% of Spaces |
1 |
|
Yes |
? |
No |
|
|
|
|
|
|
5 |
|
|
|
Innovation & Design Process |
5 Points |
|
|
|
|
|
|
|
|
|
|
1 |
|
|
Credit 1.1 |
Innovation in Design |
1 |
|
1 |
|
|
Credit 1.2 |
Innovation in Design |
1 |
|
1 |
|
|
Credit 1.3 |
Innovation in Design |
1 |
|
1 |
|
|
Credit 1.4 |
Innovation in Design |
1 |
|
1 |
|
|
Credit 2 |
LEED® Accredited Professional |
1 |
|
Yes |
? |
No |
|
|
|
|
|
|
42 |
|
20 |
|
Project Totals (pre-certification estimates) |
69 Points |
|
|
|
|
|
Certified: 26-32 points, Silver: 33-38 points, Gold: 39-51 points, Platinum: 52-69 points |
|
|
|
|
|
|
|
|
|